Lesson 5/PT = 0x21/Summary ODUj Tributary Signal Mapping/Multiplexing into an ODU4 Server Signal

This blog post includes a video that summarizes all of our training on Mapping/Multiplexing ODUj Tributary Signals into an ODU4 Server Signal.

Summary/Review – Mapping/Multiplexing ODUj Tributary Signals into an ODU4 Server Signal (PT = 0x21)

This blog post includes a video that summarizes our training on Mapping/Multiplexing ODUj Tributary Signals into an ODU4 Server Signal, using the PT = 0x21 Approach.

In particular, we briefly summarize the following topics within this video.

  • A quick review of Mapping/Multiplexing schemes that use GMP (Generic Mapping Procedure)
  • Mapping and Multiplexing as many as 80 ODU0 Tributary Signals into an ODU4 Server Signal.
  • Mapping and Multiplexing as many as 40 ODU1 Tributary Signals into an ODU4 Server Signal.
  • Mapping and Multiplexing as many as 10 ODU2 or ODU2e Tributary Signals into an ODU4 Server Signal.
  • Mapping and Multiplexing as many as 2 ODU3 Tributary Signals into an ODU4 Server Signal.
  • Mapping and Multiplexing some number of ODUflex Tributary Signals into an ODU4 Server Signal.
  • A Discussion on why we logically subdivide ODU1, ODU2, ODU2e, ODU3, and ODUflex tributary signals into time-slots (when mapping/multiplexing into a Higher-Speed ODUk Server Signal), but we don’t do that for ODU0 tributary signals.
  • A Review of the MSI (Multiplex Structure Identifier) within the ODU4 Server Signal for each Mapping/Multiplexing Schemes.

You can view this video below.

Continue reading “Lesson 5/PT = 0x21/Summary ODUj Tributary Signal Mapping/Multiplexing into an ODU4 Server Signal”

Lesson 5/PT = 0x21/16 ODU1 – Mapping/Multiplexing 40 ODU1 Tributary Signals into an ODU4 Server Signal

This blog post presents a video that describes how to map/multiplex as many as 40 ODU1 tributary signals into an ODU4 server signal using the PT = 0x21 scheme.

Mapping/Multiplexing 40 ODU1 Tributary Signals into an ODU4 Server Signal (PT = 0x21)

This blog post includes a video that shows how we map and multiplex as many as 40 ODU1 Tributary Signals into an ODU4 Server Signal, using the PT = 0x21 Approach.

In the video, we discuss the following:

  • Using the GMP (Generic Mapping Procedure) to map each ODU1 Tributary Signal into their respective ODTU4.2 signal/frames.
  • How to combine these ODTU4.2 signals and map them into an ODU4 payload.
  • Transporting these GMP Justification parameters from the Source PTE (where we map/multiplex these ODU1 tributary signals into an ODU4 server signal) to the Sink PTE (where we de-multiplex and de-map out the ODU1 tributary signals).
  • A review of the Multiplex Structure Identifier (MSI) within this type of ODU4 Signal.

You can view this video below.

Continue reading “Lesson 5/PT = 0x21/16 ODU1 – Mapping/Multiplexing 40 ODU1 Tributary Signals into an ODU4 Server Signal”

Lesson 5/PT = 0x21/4 ODU1 – Mapping/Multiplexing 4 ODU1 Tributary Signals into an ODU2 Server Signal

This blog post includes a video that shows how we can map/multiplex as many as 4 ODU1 Tributary Signals into an ODU2 Server Signal, using the PT = 0x21 Scheme.

Mapping/Multiplexing 4 ODU1 Tributary Signals into an ODU2 Server Signal (PT = 0x21)

This blog post includes a video that:

  • Shows how we map and multiplex as many as 4 ODU1 Tributary Signals into an ODU2 Server Signal, using the PT = 0x21 Approach.

In this video, we discuss the following:

  • Mapping/Multiplexing 4 ODU1 Signals into an ODU2 Server Signal using the PT = 0x21 Approach differs from doing the same via the PT = 0x20 Approach.
  • Using the AMP (Asynchronous Mapping Procedure) to map each ODU1 Tributary signal into their respective ODTU12 signal/frames.
  • How to combine these ODTU12 signals and map them into an ODU2 payload.
  • Transporting these AMP Justification parameters from the Source PTE (where we map/multiplex these ODU1 tributary signals into an ODU2 server signal) to the Sink PTE (where we de-multiplex and de-map out the ODU1 tributary signals)
  • A review of the Multiplex Structure Identifier (MSI) within this type of ODU2 signal.

You can view this video below.

Continue reading “Lesson 5/PT = 0x21/4 ODU1 – Mapping/Multiplexing 4 ODU1 Tributary Signals into an ODU2 Server Signal”

Lesson 5/PT = 0x21/Summary ODUj Tributary Signal Mapping/Multiplexing into an ODU3 Server Signal

This blog post contains a video that summarizes our training on Mapping/Multiplex ODUj Tributary Signals into an ODU3 Server Signal, using the PT = 0x21 Scheme.

Summary/Review – Mapping/Multiplexing ODUj Tributary Signals into an ODU3 Server Signal (PT = 0x21)

This blog post includes a video that summarizes our training on Mapping/Multiplexing ODUj Tributary Signals into an ODU3 Server Signal, using the PT = 0x21 Approach.

In particular, we briefly summarize the following topics within this video.

  • A quick review of Mapping/Multiplexing schemes that use GMP (Generic Mapping Procedure)
  • A quick review of Mapping/Multiplexing schemes that use AMP (Asynchronous Mapping Procedure)
  • Mapping and Multiplexing as many as 32 ODU0 Tributary Signals into an ODU3 Server Signal
  • Mapping and Multiplexing as many as 16 ODU1 Tributary Signals into an ODU3 Server Signal
  • Also, Mapping and Multiplexing as many as 4 ODU2 Tributary Signals into an ODU3 Server Signal.
  • Mapping and Multiplexing as many as 3 ODU2e Tributary Signals into an ODU3 Server Signal
  • Mapping and Multiplexing some number of ODUflex Tributary Signals into an ODU3 Server Signal
  • A Discussion on why we logically subdivide ODU1, ODU2, ODU2e, and ODUflex tributary signals into time-slots (when mapping/multiplexing into a Higher-Speed ODUk Server Signal), but we don’t do that for ODU0 tributary signals.
  • A Review of the MSI (Multiplex Structure Identifier) within the ODU3 Server Signal for each Mapping/Multiplexing Schemes.

You can view this video below.

Continue reading “Lesson 5/PT = 0x21/Summary ODUj Tributary Signal Mapping/Multiplexing into an ODU3 Server Signal”

Lesson 5/PT = 0x21/16 ODU1 – Mapping/Multiplexing 16 ODU1 Tributary Signals into an ODU3 Server Signal

This post describes how we map/multiplex as many as 16 ODU1 tributary signals into an ODU3 sever signal.

Mapping/Multiplexing 16 ODU1 Tributary Signals into an ODU3 Server Signal (PT = 0x21)

This blog post includes a video that:

  • Shows how we map and multiplex as many as 16 ODU1 Tributary Signals into an ODU3 Server Signal, using the PT = 0x21 Approach.

In particular, we discuss the following topics in this video.

  • Subdividing the ODU1 signal into two separate 1.25 Gbps time-slots.
  • Using the AMP (Asynchronous Mapping Procedure) to map the ODU1 tributary signals into their respective ODTU13 signal/frames.
  • How to combine these ODTU13 signals and map them into an ODU3 payload.
  • Transporting these AMP Justification parameters from the Source PTE (where we map/multiplex these ODU1 tributary signals into an ODU3 server signal) to the Sink PTE (where we de-multiplex and de-map out the ODU1 tributary signals).
  • Multiplex Structure Identifiers within this type of ODU3 server signal.

You can view this video below.

Continue reading “Lesson 5/PT = 0x21/16 ODU1 – Mapping/Multiplexing 16 ODU1 Tributary Signals into an ODU3 Server Signal”