The Glossary Page
#
- 8B/10B Coding
- 64B/65B Coding
- 64B/66B Coding
- 1000BASE-X
- 10GBASE-R
- 25GBASE-R
- 40GBASE-R
- 100GBASE-R
- 100GBASE-ZR
- 400GBASE-R
- 1+1 Protection Switching (APS)
- 1:n Protection Switching (APS)
A
- AIS (Alarm Indication Signal) – Generic Description
- AI_TSD – Adapted Information (Interface) – Trail Signal Degrade
- AI_TSF – Adapted Information (Interface) – Trail Signal Fail
- AMP (Asynchronous Mapping Procedure) – for non-OTN Client Signals
- Alignment Marker Block (100GBASE-R PCS Encoding)
- APS/PCC field (within the ODU Overhead) – For Linear Protection Switching
- Atomic Functions (from ITU-T G.798)
- Automatic Protection Protection (APS)
B
- Backward Defect Indicator (dBDI) – OTUk Layer
- Backward Error Indicator (BEI) – OTUk Layer
- Bidirectional Protection Switching (APS)
- Block (for Performance Monitoring and Signal Degrade Declaration Purposes at the ODU Layer)
- Block (for Performance Monitoring and Signal Degrade Declaration Purposes at the OTU Layer)
- Block (for Performance Monitoring and Signal Degrade Declaration Purposes at the TCM Layer i)
- BMP (Bit-Synchronous Mapping Procedure) – for non-OTN Client Signals
- Broadcast Communication (Definition)
C
- CAUI-4
- CAUI-10
- CBR – Constant Bit Rate
- CGMII
- CI_SSD – Characteristic Information (Interface) – Server Signal Degrade
- CI_SSF – Characteristic Information (Interface) – Server Signal Fail
- Connection-Oriented Communication (Definition)
- Connectionless Communication (Definition)
- Consequent Equations – for OTN Applications
D
- dAIS at the ODUk Layer (see ODUk-AIS)
- dAIS at the OTUk Layer (see OTUk-AIS Defect Detection)
- DAPI – Destination Access Point Identifier (for Trail Trace Identifier Messages)
- dBDI at the OTUk Layer (see OTUk-BDI Defect Detection)
- dBIAE (Backward Input Alignment Error Defect) at the OTUk Layer(*)
- dCSF (Client Signal Fail) defect – for Non-Multiplexed ODUk/OPUk traffic(*)
- dDEG at the ODUk Layer(*)
- dDEG at the OTUk Layer(*)
- dDEG for TCM Sections
- DEGM
- DEG_Thr
- Defect Condition
- Defect Correlation
- Destination Address Field (Ethernet Frame)
- Disparity (see Running Disparity)
- dIAE (Input Alignment Error) Defect at the OTUk Layer(*)
- DIX Standard Ethernet Frame
- dLCK – the Locked Defect Condition
- dLCS – Loss of Character Synchronization (100GBASE-R)
- dLOF for OTN (see Loss of Frame Defect – OTN)
- dLOFLOM[p] – Loss of Frame – Loss of Multi-Frame for ODUj Tributary Signal p (*)
- dLOL – Loss of Lane Alignment Defect (applies to OTL3.4 and OTL4.4 Applications)(*)
- dLOM for OTN (see Loss of Multi-Frame – OTN)
- dLOOMFI – Loss of OMFI Defect Condition – for Multiplexed ODU4 Traffic(*)
- dLOR – Loss of Recovery
- dLOS-P – Loss of Signal Defect – Path
- dLTC – Loss of Tandem Connection Monitoring Defect
- DMp – Round Trip Delay Measurement Bit-field – ODUk Path
- dMSIM[p] – Multiplex Structure Identifier Mismatch Defect for ODUj Tributary Signal p (*)
- DMti – Round Trip Delay Measurement Bit-field – TCM Level i Subnetwork
- dOCI – the Open Connection Indication Defect Condition(*)
- dPLM – Payload Type Mismatch – for the 100Gbps Ethernet Adaptation Sink (ODUkP/CBR_ETC100GR-g_A_Sk) Function (*)
- dPLM – Payload Type Mismatch – for Multiplexed ODUk Traffic (e.g., the ODUkP/ODUj-21_A_Sk Function) (*)
- dTIM at the ODUk Layer(*)
- dTIM at the OTUk Layer(*)
E
- Errored Block
- Ethernet Frame
- Extra Traffic Signal (APS)
F
- Far-End Defect Second – ODUk Layer (see pF_DS)
- Far-End Defect Second – OTUk Layer (see pF_DS)
- Far-End Error Block Count – ODUk Layer
- Far-End Error Block Count – OTUk Layer (see pF_EBC)
- FAS – Framing Alignment Signal
- FEC – Forward Error Correction
- Full-Duplex Communications
G
- GCC – General Communication Channel
- Generic Framing Procedure (GFP)
- Generic Mapping Procedure (GMP)(*)
H
I
- Internet Packet (IP)
- IPv4
- IPv6
L
- Linear Protection-Switching
- LLM – Logical Lane Marker
- Loss of Frame of Logical Lane (LOFLANE)
- Loss of Frame Defect – OTN (dLOF)
- Loss of Multi-Frame Defect – OTN (dLOM)
- Loss of Recovery – LOR
M
- Manchester Line Code
- Mapping Procedures (for OTN)
- MFAS – Multi-Frame Alignment Signal
- MSI (Multiplex Structure Identifier) for OTN Applications
- Multicast Communication (Definition)
New Comprehensive OTN Training…Available Now. Click on the Banner Below to Learn More!!!
Discounts Available for a Short Time!!!
N
- Near-End Defect Second – OTUk Layer (see pN_DS)
- Near-End Errored Block Count – OTUk Layer (see pN_EBC)
- NJO – Negative Justification Opportunity Byte (AMP)
- Non-Revertive Protection Switching
- Normal Traffic Signal (APS)
- NULL Signal (for OTN Applications)
O
- ODU2 Server Signals (PT = 0x21)
- ODU3 Server Signals (PT = 0x21)
- ODTU3.1 (Optical Data Tributary Unit – 1 Time-Slot – for ODU0 Tributary Signals)(*)
- ODTU13 (Optical Data Tributary Unit – 1 Time-Slot for ODU1 Tributary Signals)(*)
- ODTU23 (Optical Data Tributary Unit – ODU2 Tributary Signals)(*)
- ODTU3.9 (Optical Data Tributary Unit – 9 Time-Slots – for ODU2e Tributary Signals)(*)
- ODTU3.ts (Optical Data Tributary Unit – ts Time-Slots – for ODUflex Tributary Signals)(*)
- ODU4 Server Signals (PT = 0x21)
- ODTU4.1 (Optical Data Tributary Unit – 1 Time-Slot – for ODU0 Tributary Signals)
- ODTU4.2 (Optical Data Tributary Unit – 2 Time-Slots – for ODU1 Tributary Signals)(*)
- ODTU4.8 (Optical Data Tributary Unit – 8 Time-Slots – for ODU2/2e Tributary Signals)(*)
- ODTU4.31 (Optical Tributary Data Unit – 31 Time-Slots – for ODU3 Tributary Signals)(*)
- ODTU4.ts (Optical Tributary Data Unit – ts Time-Slots – for ODUflex Tributary Signals)(*)
- ODU (Optical Data Unit)
- ODU0 Signal – Data Rate and Characteristics
- ODU1 Signal – Data Rate and Characteristics
- ODU2 Signal – Data Rate and Characteristics
- ODU2e Signal – Data Rate and Characteristics
- ODU3 Signal – Data Rate and Characteristics
- ODU4 Signal – Data Rate and Characteristics
- ODUk_TT_So – ODU Trail Termination Source Atomic Function
- ODUk_TT_Sk – ODU Trail Termination Sink Atomic Function
- ODUk-AIS (Alarm Indication Signal)
- ODUk-LCK (Locked Indication)
- ODUk-OCI (Open Connection Indication)
- ODUT/ODUk_A_Sk – ODUT (TCM) to ODU Adaptation Sink Atomic Function(*)
- ODUT/ODUk_A_So – ODUT (TCM) to ODU Adaptation Source Atomic Function (*)
- ODUTm_TT_Sk – ODUT (TCM) Non-Intrusive Monitoring Function (*)
- ODUT_TT_Sk – ODUT (TCM) Trail Termination Sink Atomic Function(*)
- ODUT_TT_So – ODUT (TCM) Trail Termination Source Atomic Function (*)
- ODUflex Signal – Data Rates and Characteristics
- OMFI (OPU Multi-Frame Indicator)
- OPU (Optical Payload Unit)
- OSI Reference Model
- OTL3.4 Interface
- OTL4.4 Interface
- OTL4.10 Interface
- OTSi – Optical Tributary Signal
- OTSi/OTUk_A_Sk – OTSi to OTUk Adaptation Sink (Atomic) Function
- OTSi/OTUk_A_So – OTSi to OTUk Adaptation Source (Atomic) Function
- OTSiG – Optical Tributary Signal Group
- OTSiG/OTUk_A_Sk – OTSiG to OTUk Adaptation Source (Atomic) Function (OTU3/4 Applications ONLY)
- OTSiG/OTUk_A_So – OTSiG to OTUk Adaptation Source (Atomic) Function (OTU3/4 Applications ONLY)
- OTU (Optical Transport Unit) Frame
- OTUk/ODUk_A_Sk – OTUk to ODUk Adaptation Sink (Atomic) Function
- OTUk/ODUk_A_So – OTUk to ODUk Adaptation Source (Atomic) Function
- OTUk-AIS (dAIS) Defect Condition
- OTUk-AIS (Alarm Indication Signal) Maintenance Signal
- OTUk-BEI (Backward Error Indicator)
- OTUk-BIP-8 (Bit Interleaved Parity)
- OTUkV (Functionally Compliant OTUk Frames)
- OTUk_TT_Sk – OTUk Trail Termination Sink (Atomic) Function
- OTUk_TT_So – OTUk Trail Termination Source (Atomic) Function
P
- Path Monitoring BEI (PM-BEI)
- Path Monitoring BIP-8 (PM-BIP-8)
- Path Monitoring – Round-Trip Delay Measurements – using DMp
- Path Monitoring – Round-Trip Delay Measurements – using DMt1 through DMt6
- Path Terminating Equipment (PTE)
- Payload Type (PT)
- PCC – Protection Communication Channel (APS)
- PCS – Physical Coding Sublayer (Ethernet)
- Physical Layer
- pF_DS (Far-End Defect Seconds) – ODUk Layer
- pF_DS (Far-End Defect Seconds) – OTUk Layer
- pF_EBC (Far-End Errored Block Count) – OTUk Layer
- PJO – Positive Justification Opportunity Byte
- pN_DS (Near-End Defect Seconds) – OTUk Layer
- pN_EBC (Near-End Errored Block Count) – OTUk Layer
- Preamble (Ethernet Frame)
- Protection Group (APS)
- PSI (Payload Structure Identifier – OPUk)
- PT = 20 Method for Mapping/Multiplexing ODUj Signals into an ODUk Signal
- PT = 21 Method for Mapping/Multiplexing ODUj Signals into an ODUk Signal
R
- RDI (Remote Defect Indicator)
- Reliable Communication (Definition)
- Revertive Protection Switching
- Ring-Switching (within a Shared-Ring Protection-Switching System)
- Running Disparity
S
- SAPI – Source Access Point Identifier (for Trail Trace Identifier Messages)
- Scrambling
- Section Monitoring BEI (SM-BEI) – See OTUk-BEI
- Section Monitoring BIP-8 (SM-BIP-8) – See OTUk-BIP-8
- Section Monitoring Overhead (SMOH)
- Section Terminating Equipment (STE)
- Shared-Ring Protection (SRP) Switching Systems
- Simplex Communication
- Sink-Node (APS) – See Tail-End (APS)
- SNC/I – Subnetwork Connection Protection – Inherent Monitoring (Protection-Switching)(*)
- SNC/Ne – Subnetwork Connection Protection – Non-Intrusive (End-to-End) Monitoring (Protection-Switching)(*)
- SNC/Ns – Subnetwork Connection Protection – Non-Intrusive (Sublayer) Monitoring (Protection-Switching)(*)
- SNC/S – Subnetwork Connection Protection – Sublayer Monitoring (Protection-Switching)(*)
- Source Address Field (Ethernet Frame)
- Source-Node (APS) – See Head-End (APS)
- Span (within a Shared-Ring Protection-Switching System)
- Span-Switching (within a Shared-Ring Protection-Switching System)
T
- Tail-End (APS)
- TCM – Tandem Connection Monitoring
- TCM Controller – Tandem Connection Monitoring Controller Atomic Function
- TCMi-dAIS – Tandem Connection Monitoring Level i – dAIS
- TCMi-dBDI – Tandem Connection Monitoring Level i – dBDI
- TCMi-BEI – Tandem Connection Monitoring Level i – BEI
- TCMi-dBIAE – Tandem Connection Monitoring Level i – dBIAE
- TCMi-BIP-8 – Tandem Connection Monitoring Level i – BIP-8
- TCMi-dDEG – Tandem Connection Monitoring Level i – dDEG
- TCMi-dIAE – Tandem Connection Monitoring Level i – dIAE
- TCMi-dLCK – Tandem Connection Monitoring Level i – dLCK
- TCMi-dLTC – Tandem Connection Monitoring Level i – Loss of Tandem Connection Monitoring Defect
- TCMi-dOCI – Tandem Connection Monitoring Level i – dOCI
- TCMi-dTIM – Tandem Connection Monitoring Level i – dTIM
- Trail Protection
- Trail Trace Identifier (TTI) Messages
U
- Unicast Communication (Definition)
- Unidirectional Protection Switching (APS)
- Unreliable Communication (Definition)
W
- Wait-to-Restore period (or Timer)