OTN Related Topics within this Blog
General Topics
- Consequent Equations – What are they and How can you use them?
- Defect – What is the Basic Definition of a Defect?
- Defect Correlation – What is it and How should you Interpret it?
OTUk Related Topics
- What Does the OTU Layer Do and Monitor?
OTUk Framing Format and OTUk-SMOH (Section Monitoring Overhead)
- OTUk Frame Structure – Fully Compliant OTUk Frames
- OTUkV Frame Structure – Functionally Compliant OTUkV Frames
- OTUk-SMOH (Section Monitoring Overhead)
- Section Terminating Equipment (STE)
OTUk Maintenance Signals
Other Forms of OTUk Signals
OTUk-Related Defects
- dLOS-P – Loss of Signal – Path
- dLOS-P[i] – Loss of Signal – Path, for Electrical Lane i (OTL3.4/4.4)
- dLOFLANE[j] – Loss of Frame of Logical Lane j (OTL3.4/4.4)(*)
- dLOL – Loss of Lane Alignment (OTL3.4/4.4)(*)
- dLOF – Loss of Frame
- dLOM – Loss of Multiframe
- dAIS – Alarm Indication Status
- dTIM – Trail Trace Identifier Mismatch (SM-TIM)(*)
- dIAE – Input Alignment Error(*)
- dBDI – Backward Defect Indicator
- dBIAE – Backward Input Alignment Error(*)
- dDEG – Signal Degrade (SM-DEG)(*)
OTUk-Related Errors
- Forward Error Correction (FEC)
- OTUk (or SM-BIP-8) Errors
- SM-BEI Counts
OTUk-Related Performance Monitoring Parameters
- pF_DS – Far-End Defect Second
- pF_EBC – Far-End Errored Block Count
- pN_DS – Near-End Defect Second
- pN_EBC – Near-End Errored Block Count
OTUk Atomic Functions
Functions that are Applicable to OTU1 through OTU4 Rates
- OTSi/OTUk-a_A_Sk (OTSi to OTUk Adaptation Sink Function with FEC)
- OTSi/OTUk-a_A_So (OTSi to OTUk Adaptation Source Function with FEC)
- OTSi/OTUk-v_A_Sk (OTSi to OTUk Adaptation Sink Function with Vendor-Specific FEC)
- OTSi/OTUk-v_A_So (OTSi to OTUk Adaptation Source Function with Vendor-Specific FEC)
Functions that are Applicable to OTU1 through OTU2 Rates
- OTSi/OTUk-b_A_Sk (OTSi to OTUk Adaptation Sink Function without FEC)
- OTSi/OTUk-b_A_Sk (OTSi to OTUk Adaptation Source Function without FEC)
Functions that are Applicable to OTU3 and OTU4 Rates ONLY
- OTSiG/OTUk-a_A_Sk (OTSiG to OTUk Adaptation Sink Function with FEC)
- OTSiG/OTUk-a_A_So (OTSiG to OTUk Adaptation Source Function with FEC)
Functions that are Applicable to OTU3 Rates ONLY
- OTSiG/OTUk-b_A_Sk (OPSM to OTUk Adaptation Sink Function without FEC)
- OTSiG/OTUk-b_A_So (OPSM to OTUk Adaptation Source Function without FEC)
Functions that apply to ALL OTUk Rates up to OTU4
- OTUk_TT_Sk (OTUk Trail Termination – Sink) Function
- OTUk_TT_So (OTUk Trail Termination – Source) Function
- OTUk/ODUk_A_Sk (OTUk/ODUk Adaptation – Sink) Function
- OTUk/ODUk_A_So (OTUk/ODUk Adaptation – Source) Function
Interfacing a High-Speed OTUk Signal to the Outside World
- The OTL3.4 Interface(*)
- The OTL.4.10 Interface
- The OTL4.4 Interface(*)
Stuck at Home? You Can Be an Expect on OTN Before You Return to Your Office!! Click on the Banner Below to Learn More!!
Discounts Available for a Short Time!!!
ODUk Related Topics
- What Does the ODU Layer Do and Monitor?
ODUk Framing Format and ODUk-PMOH (Path Monitoring Overhead)
- ODUk Frame Structure
- ODUk-PMOH (Path Monitoring Overhead)
- Path Terminating Equipment (PTE)
Other Forms of ODUk Signals
- Extra Traffic Signal (Protection Switching)
- ODUk Trail-Trace Identification Message
- NULL Signal
ODUk Maintenance Signals
ODUk Related Defects
- dAIS – Alarm Indication Status
- dTIM – Trail Trace Identifier Mismatch (at the ODUk Layer)(*)
- dLCK – Locked Defect Condition
- dOCI – Open Connection Indicator Defect Condition
- dBDI – Backward Defect Indicator
- dDEG – Signal Degrade(at the ODUk Layer)(*)
- dLOOMFI – Loss of OMFI Synchronization Defect(*)
- dLOFLOM[p] – Loss of Frame/Loss of Multi-Frame (Multiplexed Applications Only)(*)
ODUk Atomic Functions
- ODUk_TT_Sk (ODUk Trail Termination – Sink) Function
- ODUk_TT_So (ODUk Trail Termination – Source) Function
- OTUk/ODUk_A_Sk (OTUk/ODUk Adaptation – Sink) Function
- OTUk/ODUk_A_So (OTUk/ODUk Adaptation – Source) Function
- ODUkP/ODUj-21_A_Sk
- ODUkP/ODUj-21_A_So
OPUk Related Topics
- Payload Structure Identifier
- Payload Type (PT)
- Multiplex Structure Identifier (MSI)
OPUk Related Defects
- dPLM – Payload Type Mismatch Defect
- dMSIM[p] – Multiplex Structure Identifier Mismatch – Defect – Tributary Port p.
Clueless about OTN? We Can Help!!! Click on the Banner Below to Learn More!!!
Discounts Available for a Short Time!!
Mapping of non-OTN Client Signals into OPUk/ODUk Signals
- BMP – Bit Synchronous Mapping Procedure
- AMP – Asynchronous Mapping Procedure
- GMP – Generic Mapping Procedure(*)
Multiplexing/Mapping Lower-Speed ODUj Signals into Higher-Speed ODUk Signals
PT = 0x20 – Approach to Multiplexing/Mapping
- ODU1 Server Signal
- ODU0 ⇒ ODTU01 ⇒ x4 ⇒ ODTUG1 ⇒ OPU1 ⇒ ODU1
- ODU2 Server Signal
- ODU1 ⇒ ODTU12 ⇒ x4 ⇒ ODTUG2⇒ OPU2 ⇒ ODU2
- ODU3 Server Signal
- ODU1 ⇒ ODTU13 ⇒ x16 ⇒ ODTUG3⇒ OPU3 ⇒ ODU3
- ODU2 ⇒ ODTU23 ⇒ x4 ⇒ ODTUG3⇒ OPU3 ⇒ ODU3
PT = 0x21 – Approach to Multiplexing/Mapping
- ODU2 Server Signal
- ODU3 Server Signal
- ODU4 Server Signal
Tandem Connection Monitoring (TCM) Topics
- What is Tandem Connection Monitoring, and Why Do We Need it?
- The TCMOH (TCM Overhead) Field
- Cascaded Domains
- Nested Domains
Tandem Connection Monitoring Atomic Functions
- dLTC – Loss of Tandem Connection Monitoring
- ODUT/ODU_A_So (ODUT to ODUP Adaptation Source) Function
- ODUT_TT_So (ODUT Trail Termination Source) Function
- ODUT/ODU_A_Sk (ODUT to ODUP Adaptation Sink) Function
- ODUT_TT_Sk (ODUT Trail Termination Sink) Function
- TCM Controller Function
Protection Switching (Linear)
1+1 Protection-Switching Architecture
- Permanent Bridge
1:N Protection-Switching Architecture
- Broadcast Bridge
Unidirectional Protection-Switching
Bidirectional Protection-Switching
Reverting Protection-Switching
Non-Reverting Protection-Switching
Types of Monitoring (for Protection-Switching)
SNC/I – Sub-Network Circuit/Inherent Monitoring
- What is SNC/I Monitoring – at the OTUk Layer?
- When will the Tail-End circuitry declare SF for SNC/I Monitoring – at the OTUk Layer?
- When will the Tail-End circuitry declare SD for SNC/I Monitoring – at the OTUk Layer?
- What is SNC/I Monitoring – at the ODUk Layer?
- When will the Tail-End circuitry declare SF for SNC/I Monitoring – at the ODUk Layer?
- When will the Tail-End circuitry declare SD for SNC/I Monitoring – at the ODUk Layer?
SNC/S – Sub-Network Circuit/Sublayer Monitoring
- What is SNC/S Monitoring?
- When will the Tail-End circuitry declare SF for SNC/S Monitoring?
- When will the Tail-End circuitry declare SD for SNC/S Monitoring?
SNC/Ne – Sub-Network Circuit/Non-Intrusive Monitoring – End-to-End
- What is SNC/Ne Monitoring?
- When will the Tail-End circuitry declare SF for SNC/Ne Monitoring?
- When will the Tail-End circuitry declare SD for SNC/S Monitoring?
SNC/Ns – Sub-Network Circuit/Non-Intrusive Monitoring – Sublayer
- What is SNC/Ns Monitoring?
- When will the Tail-End circuitry declare SF for SNC/Ns Monitoring?
- When will the Tail-End circuitry declare SD for SNC/Ns Monitoring
The APS/PCC Protection-Switching Protocol for Linear Protection Switching
- The APS/PCC field-format for Linear-Protection-Switching
- APS Command Priorities for Linear Protection-Switching
- The LoP (Lock-Out of Protection) Command
- The SF-P (Signal Fail in the Protection Transport Entity) Command
- The SF-W (Signal Fail in the Working Transport Entity) Command
Protection Switching (ODUk Shared Ring)
2-Fibre/2-Lambda Shared-Ring Protection-Switching Systems
4-Fibre/4-Lambda Shared-Ring Protection-Switching Systems
Span-Switching
Ring-Switching
(*) – Requires that you be a Member of THE BEST DARN OTN TRAINING PRESENTATION…PERIOD!!! to see this link.